Component Cleaning and Handling Techniques
Canon® AX,BX,EX,LX,NX,PX,VX,WX
Component Cleaning and Handling Method
Never touch the coated area of the mag roller with your fingers.
Print quality can be significantly impaired by doing so. You should
not use any type of solvent to remove residual toner from the mag
Magnetic Roller
roller surface. The best cleaning method is compressed air. OPC
case boxes are good storage areas to prevent scratches and nicks on
the mag sleeve surface.
Handle the PCR by the metal axle or use latex gloves. Apply
Anakenisis® PCR cleaner to a clean, lint free cloth, and wipe the
PCR
PCR until all residue is removed. Always wrap the PCR in a clean
cloth to prevent damage to the coated areas.
Use compressed air to remove residual toner from the surface of the
OPC. Wrap in a clean cloth, and set aside in a dark place to
minimize light exposure. Drum cases are ideal storage containers
OPC
to protect the OPC surface from light, scratches and nicks. Never
touch the coated area of the OPC with bare hands; skin oils will
cause image defects.
All urethane blades should be cleaned with a lint free cloth
Wiper/Doctor Blades
saturated with 99% IPA.
Component Cleaning and Handling Techniques
Canon® CX,SX
Component Cleaning and Handling Method
Never touch the coated area of the mag roller with your fingers
because you can impair print quality. You should not use any type
of solvent to remove residual toner from the mag roller surface.
Magnetic Roller
Instead, sue compressed air. OPC case boxes help prevent
scratches and nicks occurring on the mag sleeve surface when used
as sleeve storage areas.
The best method for cleaning the corona assembly is to soak it in an
Ultrasonic Bath. If this is not available, you can use Scotchbrite®
Corona Assembly
and a cotton swab to gently clean the wire.
Use compressed air to remove residual toner from the surface of the
OPC. Wrap in a clean cloth, and set aside in a dark place to
minimize light exposure. Drum cases are ideal storage containers
OPC
to protect the OPC surface from light, scratches and nicks. Never
touch the coated area of the OPC with bare hands; skin oils will
cause image defects.
All urethane blades should be cleaned with a lint free cloth
Wiper/Doctor Blades
saturated with 99% IPA.
Read More..
E021 The rotor fails to rotate and move properly due to a fault in the developing rotor/motor assy.
E022 Pressure fails to be applied to the developer after a specific time
passes after the developer is selected.
E023 The developer sleeve motor fails to rotate properly.
E024 The developer cannot be detected. ( not mounted properly.)
E025 Excess current of the toner delivery motor or the cartridge motor is
E030 The total counters are not functioning.
E031 The optional counters are not functioning.
E032 The counters for ASSIST are not functioning. (Disconnection of
counter pulse for ASSIST.)
E040 The lifter position signal fails to be generated due to a lifter clutch
failure.
E041 The paper deck lifter fails to be detected within a specific time.
E042 The roll paper cutting operation is not functioning properly because
the cut motor does not work, etc.
E043 An abnormal signal is detected due to a fault in the pick-up motor
for the 3-cassette deck/3.5K paper deck.
E050
A malfunction of the holding tray. A fault in the side registration is
included.
Read More..